Fixed application

Filters for soldering and welding fumes
Fixed application

With the separation efficiency of 99,997% the purified air creates clean atmosphere at workplace:
  • no health hazard through inhaling dangerous substances
  • walls, floor and machine remain clean
  • no heat loss
  • clean atmosphere at workplace
  • suction directly at emergence

Emulsion Mist Separator
FRANKE-Filter GmbH
The oil and emulsion mist is captured directly at emergence. After flowing through the pre-filter and two main filters the air is sucked by the submicron particulate airfilter of high quility which has the average separation efficiency of 99,997% (measured at fume particles of 0,3 micron according to DOP testing method).
The purified air is released through the top side of the filter. The suction efficiency can be adjusted with the help of the throttle valve which is easy to operate. For the suction of hazardous gases or solvent fumes we deliver an activated carbon stage as accessory.

Technical Description:

  • filter class EU 1 or metal fabrics for the separation of crude particles
  • two filter mats class EU 4 and EU 5, DIN 24185
    overall separation efficiency >98%
    temperature stability up to 120° C,
    self-extinguishing
  • the filter mats are placed in separate metal frames in a zigzag form (fine filter)
  • submicron particulate airfilter class S, DIN 24184
    average separation efficiency- 99,997% according to DOP-Test,
    measured at fume particles of 0,3mm
  • acessories: integrated activated carbon-filter stage for the absorbtion of hazardous gases and smells.

Ventilator

  • intake tube
  • spiral housing
  • dynamically counterbalanced radial blower wheel

Actuation

  • CHF 600: rotary current motor 0,75 kW; 2800 l/min;
    220/380 V; 50 Hz
  • CHF 1200: rotary current motor 1,10 kW; 2800 l/min;
    220/380 V; 50 Hz
  • CHF 2500: rotary current motor 3,00 kW; 2850 l/min;
    220/380 V; 50 Hz
  • < CHF 3600: rotary current motor 4,00 kW; 2880 l/min;
    220/380 V; 50 Hz

Housing

  • seal welded sheet steel
  • side maintenance door
  • air intake fitting with a throttle valve
  • varnishing according to requirement
    standard: RAL 6011 (mignonette green), grounded inside

© 1998 - 2008 · FRANKE-Filter GmbH · Wiedhof 9 · D - 31162 Bad Salzdetfurth · Fon: 0049 5064 904-0 · Fax: 0049 5064 904-18